Add to Cart
1. Furnace application
The electric resistance trolley type furnace is mainly used for boronizing the steel pipes.
The bogie hearth furnace is mainly comprised of furnace shell, lining, furnace door, furnace door lifting mechanism and door compression mechanism, bogie, bogie traction mechanism, sealing between furnace body and bogie, heating element and fixed device, and temperature control system.
2. Technical specification
2.1 Rated power: 530KW+5% (1-100%) adjustable;
2.2 Power supply: 480V, 3P, 60Hz;
2.3 Rated temperature: 1050℃(normal working temperature: 850-1000℃);
2.4 Non-load furnace temperature rise speed: ≤2 hours to 850℃;
2.5 Control zone: 6 zones+ additional 3-point temperature measurement for temperature recording. And equipped with a 3-channel 7-inch color touch screen recorder or a 3-channel paper recorder for real-time printing and recording.
2.6 Effective working size: 12000×1800×1000mm(L×W×H);
2.7 Heating element connection: Y;
2.8 Temperature uniformity: ±10℃;
2.9 Temperature measurement accuracy: ±1℃;
2.10 Temperature control method: SCR, PID regulator; Shimaden temperature controller with 485 communication interface, 10.1 inch touch screen. The touch screen can record historical data for more than 1 year, store more than 10 processes and other functions, with over-temperature alarm.
2.11 furnace surface temperature rise: <45℃;
2.12 Heating element: 0Cr21AL6Nb (strip);
2.13 Bogie face plate: ZG30Cr24Ni7SiN heat resistant steel,30mm thickness;
2.14 Loading method: Product loaded on the bogie, and then bogie moves into the furnace;
2.15 Furnace lining: High-temperature refractory brick masonry structure;
2.16 Loading capacity: 5 ton per batch;
2.17 Gas inlet: There are three DN100 stainless steel pipe gas outlets on the top of the furnace. It is simple and convenient to manually open and close at the lower part of the side of the furnace body.
2.18 Protective gas inlets: Due to the long furnace body, four DN25 gas inlet pipes are evenly arranged at the lower part of the furnace side and aggregated to the DN40 main gas inlet pipe. Each gas sub-inlet pipe and the gas main inlet pipe have manual valves to control the flow rate.
3. Componets origin
No. | Item | Q'ty and Notes |
1 | Temperature controller | Shimaden, Japan |
2 | SCR | Danxiang, Jiangsu |
3 | Resistance strip | SHOUGANG, Beijing |
4 | Heat preservation material | Luyang, Shandong |
5 | Refractory material | Yifan, Jiangsu |
6 | Reducer | Huibang, Changzhou, China |
7 | Electrical components | DELIXI |
8 | Hearth plate | Jianda, Xinghua, China |
9 | Touch screen | MCGS |
10 | 3 channel recorder | Paper-less recorder, Xiamen Yudian; Or real-time print reorder with paper, Dahua Nantong; |